Skip to content
Empty finished basement room with carpet, a shelf and a window high on the wall

Basement egress windows in Northern Colorado

When a basement needs an emergency escape window, the sizes inspectors check, how the rules differ in Fort Collins, Loveland, Greeley and Windsor, and what installation costs here.

5.7 sq ft net clear openingSill 44 in. max above floorLocal installs $4,975 to $9,000

What does a basement egress window need in Northern Colorado?

Every basement bedroom needs an emergency escape and rescue opening. Under the 2024 IRC that means at least 5.7 sq ft of net clear opening (5.0 sq ft below grade), 24 in. of clear height and 20 in. of clear width, with the sill no more than 44 in. above the floor. The window well needs 9 sq ft and must reach 36 in. out, with a fixed ladder if it is deeper than 44 in. Northern Colorado installers publish prices of about $4,975 to $9,000 per window.

Source: Larimer County, Basement Finish/Interior Alteration (2024 IRC); Basement Escape; Denver Egress Window.

The sizes inspectors check

Basement emergency escape window and window well: minimum dimensionsCross-section of a basement wall. The escape window opening must be at least 24 inches high and 20 inches wide, with at least 5.7 square feet of net clear opening (5.0 below grade), and its sill no more than 44 inches above the finished floor. Outside, the window well needs at least 9 square feet of area and must extend at least 36 inches out from the window. A well deeper than 44 inches needs a permanently attached ladder or steps that may not cut into the 36 inches by more than 6 inches. The well should drain.GradeGravel, drains to foundation drainFinished floorBasement bedroomSill 44 in. maxabove the floorEscape opening5.7 sq ft net clear min.(5.0 sq ft below grade)24 in. high, 20 in. wide min.36 in. min. out from windowWindow well9 sq ft area min.Deeper than 44 in.:fixed ladder or steps,max. 6 in. into the 36 in.clearance
Minimum dimensions under the 2024 International Residential Code, as summarized by Larimer County (revised January 8, 2026). Not to scale. Your city may add local amendments; see the table below.
Requirement (2024 IRC)Minimum or maximum
Net clear openable area5.7 sq ft (5.0 sq ft if the sill is within 44 in. of grade or below grade)
Net clear openable height24 in. minimum
Net clear openable width20 in. minimum
Sill height above finished floor44 in. maximum
Window well area9 sq ft minimum
Window well projection36 in. out from the window
Well deeper than 44 in.Permanently attached ladder or steps, intruding no more than 6 in. into the 36 in.

Source: Larimer County Community Development, Basement Finish/Interior Alteration, revised January 8, 2026. Note that the minimum height and width together (24 x 20 in.) don't reach the required area: a window at both minimums is too small.

When you need one

  • A new basement bedroom. Every sleeping room needs an escape window or exterior door, in all four cities.
  • Finishing a basement in unincorporated Larimer County. The County requires one escape opening in the basement even without a bedroom.
  • Replacing an existing escape window in Fort Collins. The City allows the same size or larger, but not less than 22 in. high, 20 in. wide and 4 sq ft of net clear opening.

Sources: Larimer County; City of Fort Collins Basement Finish Guide, page 5; Loveland IRC amendments, R310.7.

Rules by city

CityWhat's localSource
Fort CollinsNew escape window: 5.7 sq ft net clear. New window wells must be designed to drain and connect to the foundation drain if there is one.Basement Finish Guide
LovelandNew sleeping rooms in an existing basement need an escape opening; other basement alterations don't (2024 code, in effect July 1, 2026).IRC amendments
GreeleyEscape windows may sit under decks, porches and cantilevers if they open fully and have a path at least 36 in. high to a yard or court (2021 code).Ordinance 25, 2022
WindsorBasement finish plans must list window sizes and types and identify the escape windows (2024 code).Basement Finish handout
Unincorporated Larimer CountyOne escape opening required in every finished basement, plus one per bedroom.County handout

What it costs

SourceWhatPrice
Basement Escape (Northern Colorado)Code-compliant egress window, installed, by package$4,975 to $8,475
Basement EscapeWindow well replacementFrom about $2,275
Denver Egress Window (Front Range)Basic package, fully installed$5,000 to $9,000
This Old House (Fixr data)Below-ground basement egress window, prefab / custom$2,500 to $5,000 / $3,000 to $7,500
This Old HouseExcavation, including installing the well$3,000 to $7,000
This Old HouseBuilding and excavation permits, national$100 to $500

Prices as published on each website, retrieved November 26, 2026. Local installers' prices are package prices that include excavation, the well and finishing; listing them is not an endorsement. In Greeley, the City's fee formula puts the permit and City sales tax for a $6,000 job at about $249 (City of Greeley).

Before you dig

  • Check the size twice. A window at the minimum height and width still fails the 5.7 sq ft area; measure the net clear opening, not the frame.
  • Plan the drainage. Fort Collins requires new wells to be designed to drain and to connect to the foundation drain where one exists; Front Range installers also recommend a well sump pump for Colorado's spring and summer storms.
  • Pull the permit first. Inspectors need to see the opening and the well before they are covered.

Sources: Larimer County; Fort Collins Basement Finish Guide; Denver Egress Window (sump pumps); Greeley R109.4 (no covering before inspection).

Common questions

Does every finished basement need an egress window?
In unincorporated Larimer County, yes: its handout requires one emergency escape and rescue opening in the basement, plus one in every bedroom. In Loveland, new sleeping rooms in an existing basement need one, while other basement alterations do not. Check your city's rules in the table above.
Can the window well be under a deck?
In Greeley, yes, if the window can open fully and there is a path at least 36 inches high to a yard or court (Greeley's amendment to IRC R310.5). Ask your city before you plan one under a deck elsewhere.
Do I need a permit for an egress window?
Cutting a new opening in a foundation wall is structural work, and the cities we cover require permits for structural changes and basement finishes. This Old House estimates building and excavation permits at $100 to $500 depending on location.
Can I install an egress window myself?
This Old House recommends a professional for below-ground egress windows, because cutting the foundation wrongly can cause flooding, mold or structural damage. Above-ground egress windows are more realistic for experienced DIYers.

Ask NoCo AI chat

Answers come from NoCo Index pages only. Don't enter personal information.

Hi! Type a question about permits, costs or radon in Fort Collins and Greeley, and I'll answer from our guides with links to the source. Or tap a common question: